cardarine-notes.peptides6155.com › Info › Identity And Regulatory Status — What the Evidence Shows

Identity And Regulatory Status — What the Evidence Shows

By Editorial Desk · published 2025-08-20 · last reviewed 2025-09-26 · Info

This is a working overview of GW501516, written for readers who want more than a one-paragraph summary but less than a textbook.

This page was last updated on 2025-09-26 and is reviewed periodically as new material appears.

Identity and Regulatory Status

Regulatory treatment varies, but cardarine is not approved as a medicine. Sports authorities list GW501516 as a prohibited substance, and it is banned at all times under the World Anti-Doping Agency code. Many countries restrict sales for human consumption, while online vendors market it as a research chemical. Such products may lack purity data, and their actual contents can differ from the label. Purchasing or possessing cardarine may carry legal consequences depending on jurisdiction. The compound is not a dietary supplement ingredient in regulated markets.

Clinical development stopped after rodent studies showed tumors at multiple sites. Whether those findings predict human cancer risk remains an open question, but they led sponsors to discontinue programs. Human safety data are limited to small, short-term studies that were not designed to assess cancer risk. Reported effects in those studies included changes in blood lipids, but the evidence is insufficient for medical use. Long-term consequences of nonmedical use are not well characterized. Questions about dose, duration, and individual susceptibility remain unresolved.

Cardarine is a common name for GW501516, an investigational compound developed in the 1990s for metabolic conditions. It acts as an agonist at peroxisome proliferator-activated receptor delta, a nuclear receptor involved in lipid and energy metabolism. The compound is frequently mislabeled as a selective androgen receptor modulator, or SARM, but its molecular target is different. GW501516 reached early clinical testing before development was discontinued. It has no approved therapeutic use in any country. The name cardarine is not a formal international nonproprietary name.

Detection, Regulation, and Quality Context

Cardarine can be detected in biological samples and product materials using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The method separates compounds by chromatography and identifies them by mass-to-charge transitions, allowing low-level detection in urine or blood. Sample preparation often involves enzymatic hydrolysis, solid-phase extraction, or protein precipitation. Certified reference materials and isotope-labeled internal standards improve quantification. Detection windows depend on metabolism, matrix, and assay sensitivity, so no single universal window applies.

Regulatory treatment of cardarine differs by context and jurisdiction. In competitive sport, the World Anti-Doping Agency lists PPARδ agonists, including GW501516, as prohibited at all times. Outside sport, it lacks approval as a prescription medicine in major drug markets, and products sold for human consumption may be treated as unapproved drugs. Some countries also restrict importation or sale through general consumer protection and medicines laws. These classifications affect availability, testing, and legal risk without establishing therapeutic value.

Because cardarine is not an approved medicine, no pharmacopeial monograph defines its identity, purity, or storage requirements. Laboratories typically rely on in-house methods and reference standards when testing materials labeled as GW501516. Certificates of analysis may report purity and identity for a specific batch, but their scope varies and they do not guarantee safety or legal status. Independent verification can include high-performance liquid chromatography, mass spectrometry, nuclear magnetic resonance, and elemental analysis. The distinction between research chemical labeling and human use is significant because quality standards and oversight differ.

Cardarine at a glance

PropertyValueNotes
Common synonymsGW501516; GW-1516; endurobolGW501516 is the research code
Drug classPPARδ agonistNot a selective androgen receptor modulator
Molecular formulaC21H18F3NO3S2Established chemical formula
Molar mass453.5 g/molCalculated from the formula
Regulatory statusProhibited in sport; not approved as medicineStatus varies by country

Preclinical Findings and Safety Signals

Safety concerns emerged from long-term animal studies. In rodents given the compound for extended periods, researchers found an increased incidence of certain cancers, including liver and bladder tumors. These findings contributed to the discontinuation of clinical development. Whether similar risks apply to short-term or low-level exposure in humans is not established, and controlled human safety data are limited. The relevance of high-dose rodent carcinogenicity findings to human use remains a subject of debate.

Human trials of GW501516 were small and short in duration. They examined lipid levels, glucose handling, and other metabolic markers, but the programs were halted after the animal cancer findings. No approved therapeutic product exists, and published human data are insufficient for establishing long-term safety. Reports of use for athletic performance come mainly from non-clinical settings and cannot be verified through controlled trials. Independent testing of products sold as cardarine has found inconsistent purity and labeling.

Laboratory studies indicate that GW501516 activates PPARδ, a nuclear receptor involved in fatty acid oxidation and energy metabolism. In rodent experiments, treated animals often showed increased endurance and reduced fat mass. These effects were observed under controlled conditions and do not establish safe or effective use in humans. The exact dose-response relationship in humans remains poorly characterized. Species differences in metabolism can affect how results translate across animals and people.

Related pages on this site

Regulatory Status and Detection Context

Cardarine is not approved for human therapeutic use in any major jurisdiction. It appears on the World Anti-Doping Agency Prohibited List as a PPARδ agonist within the hormone and metabolic modulators category. Sports organizations test for it because it has been detected in athlete samples and seized products. Regulatory actions against marketed research chemical versions have occurred in several countries, though enforcement varies. Availability through unregulated channels complicates oversight.

Analytical laboratories typically identify cardarine and its metabolites using liquid chromatography-tandem mass spectrometry. Urine is a common matrix in anti-doping testing, while blood and tissue may be used in research settings. Detection windows depend on the assay, the sample matrix, and the compound's metabolism. Because cardarine is extensively metabolized, laboratories often target specific metabolites to improve sensitivity and confirmation. Reference standards are required for reliable quantification. Method validation includes checks for selectivity, linearity, and carryover.

A persistent misconception is that cardarine is a fat-burning drug or a safe alternative to anabolic steroids. No approved therapeutic product exists, and human safety data are limited. The tumor findings in rodents remain a central concern in scientific reviews. Products sold online may contain inaccurate labels, impurities, or different compounds entirely, which complicates any assessment of effects. Independent testing of such products has reported frequent mislabeling. For these reasons, discussions in the literature emphasize risks and unknowns rather than benefits.

Detection, Stability, and Quality

Laboratory detection of GW501516 commonly uses liquid chromatography coupled with tandem mass spectrometry. The method can identify the parent compound or its metabolites in urine and blood after sample cleanup. Protein precipitation, solid-phase extraction, or enzymatic hydrolysis may precede analysis, depending on the matrix. Reference standards are required for accurate quantification and confirmation. Because the compound is not approved, testing often occurs in anti-doping, forensic, or research settings rather than routine clinical care. Results are reported with limits of detection and quantification.

Stability of GW501516 depends on form, temperature, light exposure, and moisture. Solid reference material is typically stored frozen or refrigerated in a desiccator and protected from light. Solutions in organic solvents such as dimethyl sulfoxide are often kept frozen in aliquots to reduce freeze-thaw cycling. Aqueous solubility is low, so aqueous stock solutions can be difficult to prepare without cosolvents. Degradation may appear as changes in chromatographic purity or mass spectral signal. Stability studies are needed to establish shelf life for any specific preparation.

Quality assessment for cardarine samples usually combines identity, purity, and impurity testing. Nuclear magnetic resonance spectroscopy and mass spectrometry can confirm molecular structure, while high-performance liquid chromatography estimates purity. Certificates of analysis from testing laboratories may list these results, but they do not establish safety or legality. In the absence of approved manufacturing, products sold online may contain the wrong compound, variable amounts, or unlisted contaminants. Independent verification is therefore central to analytical work and to interpreting any reported biological activity.

Reference notes

Some cecropins (e.g. cecropin A, and cecropin B) have anticancer properties and are called anticancer peptides (ACPs). Hybrid ACPs based on Cecropin A have been studied for anticancer properties. The fruit fly Defensin prevents tumour growth, suspected to bind to tumour cells owing to cell membrane modifications common to most cancer cells, such as phosphatidylserine exposure. Cecropin A can destroy planktonic and sessile biofilm-forming uropathogenic E. coli (UPEC) cells, either alone or when combined with the antibiotic nalidixic acid, synergistically clearing infection in vivo (in the insect host Galleria mellonella) without off-target cytotoxicity. The multi-target mechanism of action involves outer membrane permeabilization followed by biofilm disruption triggered by the inhibition of efflux pump activity and interactions with extracellular and intracellular nucleic acids. Recently there has been some research to identify potential antimicrobial peptides from prokaryotes, aquatic organisms such as fish, and shellfish, and monotremes such as echidnas.

BOP (benzotriazol-1-yloxytris(dimethylamino)phosphonium hexafluorophosphate) is a reagent commonly used for the synthesis of amides from carboxylic acids and amines in peptide synthesis. It can be prepared from 1-hydroxybenzotriazole and a chlorophosphonium reagent under basic conditions. This reagent has advantages in peptide synthesis since it avoids side reactions like the dehydration of asparagine or glutamine residues. BOP has used for the synthesis of esters from the carboxylic acids and alcohols. BOP has also been used in the reduction of carboxylic acids to primary alcohols with sodium borohydride (NaBH4). Its use raises safety concerns since the carcinogenic compound HMPA is produced as a stoichiometric by-product. PyBOP, a related phosphonium reagent for amide bond formation PyAOP, a related phosphonium reagent for amide bond formation

Individuals with 3-M syndrome have severe prenatal growth retardation due to growth delays during fetal development resulting in a low birth weight. Growth delays continue after birth throughout childhood and adolescence, ultimately leading to a short stature. Growth delays and immature bone development (growth retardation and delayed bone maturation) typically continue after birth (postnatally), leading to short stature (dwarfism) with proportional development of the arms and legs (as opposed to short stature with abnormally small arms and legs). In most cases, infants with 3M syndrome are unusually small and have a low birth weight despite being carried to term.

Sources: en.wikipedia.org

Notes from published material

Ketone bodies can be used as fuels, yielding 22 ATP and 2 GTP molecules per acetoacetate molecule when oxidized in the mitochondria. Ketone bodies are transported from the liver to other tissues, where acetoacetate and beta-hydroxybutyrate can be reconverted to acetyl-CoA to produce reducing equivalents (NADH and FADH2), via the citric acid cycle. Ketone bodies cannot be used as fuel by the liver, because the liver lacks the enzyme β-ketoacyl-CoA transferase, also called thiolase. Acetoacetate in low concentrations is taken up by the liver and undergoes detoxification through the methylglyoxal pathway which ends with lactate. Acetoacetate in high concentrations is absorbed by cells other than those in the liver and enters a different pathway via 1,2-propanediol. Though the pathway follows a different series of steps requiring ATP, 1,2-propanediol can be turned into pyruvate.

Macrophages can be stimulated by T cell secretion of interferon. After this activation, macrophages are able to express MHC class II and co-stimulatory molecules, including the B7 complex and can present phagocytosed peptide fragments to helper T cells. Activation can assist pathogen-infected macrophages in clearing the infection. Deriving from monocytes, a type of white blood cell, they will circulate in the blood and enter affected sites and differentiate from monocytes to macrophages. At the affected site, the macrophage surrounds the site of infection or tissue damage with its membrane in a mechanism called phagocytosis.

Ancestim is a recombinant methionyl human stem cell factor, branded by Amgen as StemGen. It was developed by Amgen and sold to Biovitrium, now Swedish Orphan Biovitrum, in December, 2008. It is a 166 amino acid protein produced by E. coli bacteria into which a gene has been inserted for soluble human stem cell factor. It has a monomeric molecular weight of approximately 18,500 daltons and normally exists as a noncovalently associated dimer. The protein has an amino acid sequence that is identical to the natural sequence predicted from human DNA sequence analysis, except for the addition of an N-terminal methionine retained after expression in E. coli. Because Ancestim is produced in E. coli, it is nonglycosylated. Ancestim is supplied as a sterile, white, preservative-free, lyophilised powder for reconstitution and administration as a subcutaneous (SC) injection and is indicated for use in combination with filgrastim for mobilizing peripheral hematopoietic stem cells for later transplantation in certain cancer patients.

There are several national and international bioanalytical organisations active throughout the world. Often they are part of a bigger organisation, e.g. Bioanalytical Focus Group and Ligand Binding Assay Bioanalytical Focus Group, which are both within the American Association of Pharmaceutical Scientists (AAPS) and FABIAN, a working group of the Analytical Chemistry Section of the Royal Netherlands Chemical Society. The European Bioanalysis Forum (EBF), on the other hand, is independent of any larger society or association.

Sources: en.wikipedia.org

Frequently asked questions

Is cardarine a SARM?

No. Cardarine is GW501516, a PPARδ agonist, while SARMs act on androgen receptors. The two classes are often grouped in informal discussions despite different mechanisms.

Is cardarine approved for human use?

No. It has no approved medical indication in any country. Regulatory agencies have not cleared it for treatment or prevention of any condition.

Why was its development discontinued?

Early clinical work stopped after rodent carcinogenicity findings. Those animal results raised concerns about long-term human risk, although direct human evidence is lacking. The human relevance of the tumors remains an open scientific question.

How is cardarine detected in anti-doping tests?

Anti-doping laboratories typically use LC-MS/MS to detect GW501516 and its metabolites in urine. The method is sensitive and can identify the compound at low concentrations. Detection depends on sample timing, metabolism, and the specific assay.

Network